TestEquity
Phenix
Phenix

Phenix 475-20 Hipot Tester, Portable, 0-75kVDC, 20mA, Manual Control of Output Voltage

Our Part #20015373

Mfr Part #475-20

Phenix 475-20
Phenix
Phenix

Phenix 475-20 Hipot Tester, Portable, 0-75kVDC, 20mA, Manual Control of Output Voltage

Our Part #20015373

Condition:New

Mfr Part #475-20

$10,290.00EACH
  • 75kV DC 20mA Hipot
  • High voltage On/Off push buttons with indicators
  • Slow and fast-acting transient protection on all meters and relays
  • Built-in discharge circuit
  • Thermal resettable overload protecting high voltage transformer primary circuits
  • Guard mode for accurate current measurements
  • Very low ripple, <2% RMS at full output
  • Filtered voltage doubler circuit, equivalent to full wave rectification
  • Digital multi-range metering
  • Circuit breaker protection
  • External interlock provision
  • Zero Start interlock

Phenix Technologies offers a line of portable 40-200 kV DC Hipots with many advanced features including high accuracy digital meters, analog charging current meter, adjustable overcurrent, and high output current ratings.

The high voltage is generated by a filtered high voltage doubler circuit, that is built by Phenix for this application.

A solenoid operated discharge switch quickly discharges the load after testing. All high voltage components are housed in an oil filled aluminum sealed grounded dead tank. A shielded high voltage lead allows the operator to safely connect the high voltage output to the test object. The high mA charging current, which is standard with all Phenix DC Hipots allows the operator to quickly and efficiently charge large capacitive loads.

The precision metering measured off the high voltage output indicates the output voltage and leakage current on large easy to read digital meters. An analog meter is provided for reading leakage current.

Additional safety features include an instantaneous and thermal overload protection for the operator and the test object.

The proven and rugged design coupled with precision metering and ease of use have made Phenix DC hipots the optimal choice.


Brand: Phenix
Frequency: 50/60 Hz
Includes: 475-20 Cables included, Input Power 7ft (2 m), High Voltage 20ft (6 m), NIST Calibration Certificate, Ground 20ft (6 m), Return 20ft (6 m), Power Interconnect n/a
Type: Hipot Tester
$10,290.00EACH
Putting Innovation to the Test

Copyright © 1996–  TestEquity LLC.
All rights reserved.