$1,830.99EACH
- Description
- Specifications
- Documents
Fluke 773
- Best in class 0.2% accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without ”breaking the loop”
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Measure 4 to 20 mA signals with in-circuit measurement
Environmental Specifications | |
Diameter of measurable conductor | 0.177 inch or 4.5 mm max |
Operating temperature | -10 to 50°C |
Storage Temperature | -25 to 60°C |
Operating Humidity | < 90% @ <30 °C, < 75% @ 30 to 55°C |
Operating Altitude | 0 to 2000 m |
IP Rating | IP 40 |
Size | 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) |
Weight | 410 g, (14.4 oz) |
Vibration | Random 2 g, 5 to 500 Hz |
Shock | 1 meter drop test (except the jaw) |
EMI/RFI | Meets EN61326-1 Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. |
Temperature Coefficient | 0.01% °C (<18°C or > 28°C) |
Power, battery life | (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms |
Warranty | Three years for electronics one year for cable and clamp assembly |
Functional Specifications | |
mA measurement (Measured by clamp) 771/772/773 |
Resolution and Range: 0
to 20.99 mA Accuracy: 0.2%+2 counts Resolution and Range: 21.0 mA to 100.0 mA Accuracy: 1% + 5 counts |
mA measurement (Measured in series with test jacks) 772/773 |
Resolution and Range: 0
to 24.00 mA Accuracy: 0.2% + 2counts |
mA source (Maximum mA Drive: 24 mA into 1,000 ohms) |
Resolution and Range: 0
to 24.00 mA Accuracy: 0.2% + 2counts |
mA simulate (Maximum voltage 50 V dc) |
Resolution and Range: 0
to 24.00 mA |
Voltage source (2 mA maximum drive current) | Resolution and Range: 0
to 10.00 V dc Accuracy: 0.2% + 2counts |
Voltatge Mesaure | Resolution and Range: 0
to 30.00 V dc Accuracy: 0.2% + 2counts |
What’s the difference between the 77X models?
Fluke 771 | Fluke 772 | Fluke 773 | |
Non-contact mA loop measurement | Integrated mA loop troubleshooting | Advanced process troubleshooting | |
mA measure, jaw | • | • | • |
mA measure, in circuit | • | • | |
Loop power | • | • | |
mA source | • | • | |
DCV measure | • | ||
DCV source | • | ||
mA scaled output | • | ||
mA in / out | • |
Brand: Fluke
$1,830.99EACH