Half Cube Model 105 Temperature Chamber Specifications

Temperature Range
-40°C to +130°C
Control Tolerance
±0.5°C (±0.2°C Typical) (Measured at the control sensor after stabilization)
Uniformity
±1.0°C (Variations throughout the chamber after stabilization)
 
Cool Down Transition Time (empty)*
Start Temp End Temp
+23°C 0°C -10°C -20°C -30°C -35°C -40°C
+23°C Standard ---- 3 min 5 min 7 min 10 min 13 min 22 min
50 Hz Export Version ---- 3 min 5 min 7 min 11 min 15 min 24 min
+85°C Standard 8 min 13 min 15 min 17 min 20 min 23 min 31 min
50 Hz Export Version 9 min 14 min 16 min 18 min 21 min 27 min 41 min
Heat Up Transition Time (empty)*
Start Temp End Temp
+23°C +50°C +85°C
+23°C ----- 1.5 min 6 min
0°C 2 min 4 min 7.5 min
-20°C 3 min 5 min 8 min
-40°C 4.5 min 7.5 min 11 min

Rate Of Change
To calculate rate of change for a particular condition, take the difference between the Start Temp and End Temp and divide by the Transition Time.
Cool Down Example (empty): From +85°C to -20°C = 105°C / 17 min = 6.18°C/min.
Heat Up Example: From -40°C to +85°C = 125°C / 11 min = 11.36°C/min.

*Note: Transition times are measured after a 30 minute soak at the respective start temperature.

 
Live Load Capacity
+23°C 0°C -10°C -20°C -30°C -40°C
200 Watts 175 Watts 165 Watts 145 Watts 90 Watts 10 Watts
 
Refrigeration and Heating System
Compressor 1/3 HP Copeland hermetic
Condenser Air Cooled
Heat of Rejection 3,000 BTUH (maximum rated chamber load at maximum cooling rate from high temperature soak)
Heater Power 500 Watts
Instrumentation
Temperature Controller 16 steps, 2 profiles, ramp and soak programmable memory. RS-232C interface. Watlow Series 96.
Limit Controller Independent of temperature controller. User adjustable high and low temperature limits. Shuts down the chamber if limits are exceeded. Watlow Series SD.
 
Power Requirements
Input Voltage Standard Model 105
120 V nominal (110 to 126 VAC), 60 Hz, 1 PH
Max Current Draw 10 A, Recommended Minimum Service 15 A
Export Model 105-EX
230 V nominal (209 to 253 VAC), 50 Hz, 1 PH
Max Current Draw 5 A, Recommended Minimum Service 10 A
Physical Characteristics and Safety
Inside Dimensions 12" W x 9" H x 8" D, 0.5 cubic feet
(305 x 229 x 203 mm, 14 liters)
Outside Dimensions
(nominal)
16.5" W x 26" H x 20" D
(419 x 660 x 508 mm)
Door latch adds 2" (51 mm) to width. Circulator motor housing adds 2" (51 mm) to depth in rear
Minimum Installed Clearance 12" (304 mm) from the rear
Access Ports 2" (51 mm) Port on left and right side (two total)
Supplied with silicone foam plugs
Weight Chamber Weight: 114 pounds (52 kg)
Shipping Weight: 140 pounds (64 kg)

NOTE: Performance is typical and based on operation at 23°C (73°F) ambient and nominal input voltage. Designed for use in a normal conditioned laboratory. Operation at higher ambient temperatures will result in decreased cooling performance. Low end limit derates to -38°C when operating above 27°C (80°F) ambient. Operation above 30°C (85°F) or below 16°C (60°F) ambient is not recommended.